Bmw Inpa 4.4 7 Download
- BMW Folding Mirrors Coding by INPA K+DCAN and NCX Expert Optional Solutions: BMW ISTA-D Not Work Where to download 04.2017 BMW ISTA 4.04.31 and ISTA-P 3.61.2?
- A forum community dedicated to BMW owners and enthusiasts. Come join the discussion about Bimmerfest events, production numbers, programming, performance, modifications, classifieds, troubleshooting, maintenance, and more! Bringing the BMW community together.
INPA BMW Software Download. INPA BMW Software Installed Notice. How to Install INPA BMW Software V5.02. Install INPA BMW Software. Connect INPA BMW Cable with the laptop. Install INPA BMW Software Driver. 8.INPA BMW Real Car Test. 9.INPA BMW Software Trouble Shooting. 10.INPA BMW Software FAQ. Load up INPA (.ipo), check the Battery and Ignition dots are black. Close INPA, but leave EDIABAS Server running in task-bar. Start DIS and wait for it to fully load. Load up Diag Head and click run. Load up IFHsrv32.exe. Enter Administration Calibrating Touch Shield in DIS. Perform API-test, check it passes, exit back to DIS. BMW ISTA-D/P works in windows 7, 8 (8.1), 10 without problem. Look here: BMW ista software download with Windows 7, Window 8, Windows 10 installation tutorials (updated in 01-2019) For BMW ISTA-D/ISTA-P interface,here recommend you to use: BMW ICOM Next A + B + C (WITHOUT SOFTWARE) VXDIAG VCX SE for BMW Diagnostic and Programming Tool (WITH.
How-to: install BMW INPA 5.0.6 software on Windows 7 or Windows 8 32 bit or 64 bit to get it to work with a K+DCAN cable.
Software version: INPA 5.0.6
Operation system:
Windows 7 32 or 64 bit
Windows 8 32 or 64 bit
Installation tips and guides:
STEP 1: INSTALLING BMW STANDARD TOOLS
STEP 2: INSTALLING INPA
STEP 3: INSTALLING NCSEXPERT IN ENGLISH
STEP 4: INSTALLING & CONFIGURATING DCAN INPA CABLE
STEP 5: CHANGING THE OBD.INI
STEP 6: SPDATEN FILES
In detail…
STEP 1: INSTALLING BMW STANDARD TOOLS
Download and install BST 212
Since BST (BMW Standard Tools) was designed for Win XP 32bit operating
Systems, users have faced issues with tools like WinKFP and NCSExpert since Win
7 64bit systems have been introduced. Running in XP compatibility mode just
wasn’t enough. Presenting you with several errors or not running at all. Only
solution was to install on a XP system or like me… XP VMware. Well that all
changed with BST 2.12 which works on 32 or 64bit systems.
WIN 7/8, 32/64bit OS
STEP 2: INSTALLING INPA software
(will need it after coding certain modules such as DME for CAS
or EWS Alignment)
Download and install my version of INPA 5.06 with Fxx Support by simply
replacing the existing folders with the folders provided in the
Replace C:EC-AppsINPA
Replace C:EDIABAS
STEP 3: INSTALLING NCSEXPERT IN ENGLISH
Download and install NCSEXPER32_ENG.zip
Copy and replace contents in the .zip file with contents in C:NCSEXPERBIN. Now
NSCExpert is in English but you will find the Hot Keys do not work. This is a bug a
fellow MHH member discovered and haven’t really worked on trying to fix it so for
the time being just click on the F# key with your mouse.
Not done yet with NCSExpert. Need to import profiles to NCSExpert. How? well
download the PFL.zip and copy and replace all contents from PFL.zip
to [b]C:NCSExpertPFL. (you will also find a lot more PFL’s by searching for
NCSExpert profiles in Google)
Now you have a working WinKFP and NCSExpert with profiles loaded on your PC
we can continue to Step 4.
STEP 4: INSTALLING & CONFIGURATING DCAN INPA CABLE
Configure your DCAN/INPA cable. If you followed my steps correctly than your
EDIABAS should already be configured to STD:OBD for use with the INPA cable. If
not you can download ediabas-konfigurator from here if it is not already in
your C:EDIABASEdiabas-Konfigurator folder. This tool allows you to easily
change the ediabas.ini to your desired interface. So if you are switching
from INPA to E-Sys you could use this to switch from STD:OBD to ENET.
Now to set your COM Port we must first find which COM port is being used for
your cable.
Connect your cable to your PC (some may require a 12v supply to power the
cable)
Allow the device drivers to install (for best driver use the driver that came with
your cable. If not then let windows install the best suitable driver for it)
Navigate to Control Panel, Device Manager, and scroll to Ports (COM & LPT)…look at the pic
So in my case it’s COM5. So we need to change this in the obd.ini file located in
the c:ediabasbin folder. But first lets make some changes to the cable.
Right click on your INPA cable driver for example mine is labelled “USB Serial
Port” and click on properties. Now in the property window click on the advanced
tab.
Now every driver is different but the important part is the settings such as latency
timer and received and transmit bytes. See pic bellow for the ideal settings. You
may also change the COM port number here as well for tutorial I left it at 5. Once
your changes are done we can proceed by clicking OK to accept the changes. No
close all windows to return to the desktop.
STEP 5: CHANGING THE OBD.INI
Navigate to C:EDIABASBIN and find file obd.ini and open it with an editor such
as notepad.
First 3 lines will look like this…
[OBD]
Port=Com1
Hardware=USB
So we need to change the Port to reflect our INPA cable which in our case is COM
port 5. So change it to look like this…
[OBD]
Port=Com5
Hardware=USB
When done click File -> Save and exit out.
Very important to remember which USB port you connected your cable to as
plugging it into a different USB port will allocate the INPA cable to a different
COM port and neither tool will see the cable until the original USB port is used
again or changed in device manager and obd.ini as mentioned above.
Now to test if your cable installed correctly. Plug it into the vehicle’s OBD port and
open INPA. You should look like this…
If not follow the above steps again and correct your error.
STEP 6: SPDATEN FILES
Download and install SPDaten files of your choice (always recommend the latest)
in this case it is 51.2. Once downloaded you can now follow the instructions
provided bellow labelled “How_to_start_WinKFP.pdf” this will explain how to
import the SPDaten files to WinKFP.
Edit to update:
For NCSExpert to install or update the daten files, copy the files from SP-daten-
E##daten to the C:NCSEXPERDATENE## (where E## is whatever chassis
you’re updating). You will also want to copy the files from SP-daten-
E##SGDAT to C:NCSEXPERSGDAT (they’re not separated into different chassis
in NCS Expert, so you just want to copy and paste everything to that directory.
Overwrite everything it asks about). Then copy the files from SP-daten-E##ECU
to C:EDIABASECU
After copying the daten files to c:NCSEXPERDATENE## copy the following files
to the following locations:
copy C:NCSEXPERDATENE##*.000 C:NCSEXPERDATEN
copy C:NCSEXPERDATENE##*.DAT C:NCSEXPERDATEN
copy C:NCSEXPERDATENE##*.ASC C:NCSEXPERDATEN
who like this article also viewed:
BMW INPA Software is BMW diagnostics software that connects to all the systems and modules on BMW cars, not just engine like generic scanners, it reads BMW trouble codes and gives live diagnostics and data and GUI pages and test functions. BMW INPA software works with INPA K+DCAN Interface. VXDAS.COM has INPA K+DCAN cable with and without switch for BMW. Here provide INPA windows 7 download link here.
INPA Windows 7 Download
Software version: 5.0.2 (tested ok)
VXDAS team also glad to share the installation guide for INPA software with Win7 32bit. Check details below:
We suggest to start with a fresh Windows 7 32 bit to get the BMW INPA software done, because this can help to collect necessary configuration files of INPA 5.0.2.
To avoid further problems, it’s better to disable Windows auto update during the INPA Windows 7 installation process.
After entering your product key, screen will pop up security message.
Select ‘Ask me later’, this will prevent Windows 7 from automatically installing any updates.
Note:
If your installing from pre-SP1 Windows 7 media, we’d rather highly recommend that you manually install two Microsoft updates:
First one: System Update Readiness Tool (KB947821):
https://www.microsoft.com/en-us/download/details.aspx?id=3132
Second one: Windows 7 Service Pack 1 (KB976932):
https://www.microsoft.com/en-us/download/details.aspx?id=5842
During testing pre-SP1 Windows 7 no longer displayed a mouse pointer, after successfully installing EDIABAS & WinKFP and rebooting the system.
Follow steps 2 through 6 of the installation guide. During the EDIABAS & WinKFP install (step 3), select Windows XP (this is not mentioned in the installation guide.)
For all other selections, accept the default and click Weiter which is German for ‘further’.
The first time you attempt to install EDIABAS & WinKFP (step 3), regsvr32 maybe fail to register two Windows ActiveX controls.
Certainly, this is normal, upon re-installation everything will work properly.
Click on OK and then click on the large red circle with a white X at the bottom of the screen to see the second regsvr32 error.
Then click on OK to acknowledge the second error.
Press any key to exit the EDIABAS OBD setup program. Don’t be concerned about any registry key warnings, this installation of EDIABAS will never be used.
When prompted to reboot, select Nein for ‘No’ and then click on Beenden or ‘End’ to exit the installation program. Go to Control Panel and uninstall the program.
Once you have uninstalled the program, reinstall it. On the second attempt, the ActiveX controls will register properly.
This time, select Ja for ‘Yes’ and reboot.
Even with SP1 installed, on occasion the system will no longer display a mouse pointer after rebooting the system at this point.
If this happens, depress the Windows logo key (on some keyboards it may have an icon of a house instead) to display the Start menu.
Depress the right arrow key once and then depress Enter to initiate a proper shutdown. When powered back on, the system should have a functional mouse pointer.
Continue with steps 4-6 in the installation guide.
At the completion of step 5, the Windows Program Compatibility Assistant may appear. So click on ‘This program installed correctly.’
At this point you could optionally install the latest EDIABAS/INPA update (ES-76) from FAL’s EA-90X distribution.
We don’t recommend doing so as the latest INPA scripts are in German and not necessary for coding.
Now you have the base INPA scripts and configuration files that you’ll need to get the latest version of INPA (5.0.6) up and running.
Then copy the the INPA CFGDAT and SGDAT folders to removable media for safe keeping. They are located in C:EC-APPSINPA.
If you were to install the K+DCAN drivers from Windows Update, set the cable to COM1, etc.
Now the battery and ignition clamps maybe working properly.
INPA 5.0.2 is are not totally compatible with the latest SP Daten files (i.e. 50.2). So let’s move on to installing BMW Standard Tools 2.12.
Links to BMW Standard Tools 2.12 and NCS Expert profiles can be found in this post:
https://www.e90post.com/forums/showpost.php?p=13792990&postcount=4476
SP Daten 50.2 can be found in this thread:
https://www.e90post.com/forums/showthread.php?t=882353
Blow away your previous installation of Windows and start over with a fresh install. INPA 5.0.2 made changes to the Windows registry etc.
Now that we have the two folders needed to bootstrap INPA 5.0.6, it’s best to reinstall Windows.
If your installing from pre-SP1 Windows 7 media, don’t forget to install the System Update Readiness Tool (KB947821). And also Windows 7 Service Pack 1 (KB976932.)
In addition, because this will hopefully be your final re-installation of Windows, we suggest that you manually install one additional Microsoft update:
Microsoft .NET Framework 4.5.1:
https://www.microsoft.com/en-us/download/details.aspx?id=40779
When the K+DCAN cable is initially plugged in, Windows will indicate that the device driver was not successfully installed.
Click on the white box circled above when it appears to change the driver update settings.
Click on ‘Change setting’
Select ‘Always install the best driver software from Windows Update’ then click on Save Changes’
Windows Update will install the latest FTDI drivers needed for the one stop electronics.com K+DCAN cable.
Please notice that the FTDI driver has defaulted to USB Serial Port COM3.
You also need to change this to COM1 and then click on ‘Close’
Click on the Windows Start button to display the Start menu.
In the Start Search box type the following command and depress Enter to launch Device Manager:
Code:
mmc devmgmt.msc
When Device Manager opens, click on the arrow to the left of ‘Ports (COM & LPT)’ to expand the Ports device tree. After that, double-click on ‘USB Serial Port (COM3)’ to open the device properties.
Click on the ‘Port Settings’ tab and then click on the ‘Advanced’ button to display the Advanced Settings for COM3.
Then change the COM Port Number to COM1 and the Latency Timer to 1 msec and click ‘OK’
The USB Serial Port should be set to COM1. Close Device Manager.
Install BMW Standard Tools 2.12.
Accept the defaults and then click ‘Next’
When prompted to select additional tasks, de-select the ‘Execute backup and restore wizard’ selections under Data backup.
You don’t have an existing installation of BMW Standard Tools to backup. Click ‘Next’
Click ‘OK’ to acknowledge that the backup wizard has been deactivated.
When the Hardware Interface Settings screen appears, select ‘USB to serial adapter’ then click ‘Next’
Then click ‘Finish’ to complete the BMW Standard Tools setup and restart your computer.
When the User Account Control dialog box appears, select Yes to allow the Windows Command Processor to make changes to your computer.
Copy the Windows ActiveX control MSFLXGRD.OCX to C:WINDOWSSYSTEM32 and manually register it.
Then copy the Windows ActiveX control RICHTX32.OCX to C:WINDOWSSYSTEM32 and manually register it.
Overwrite the INPA initialization file in the C:EC-APPSINPACFGDAT folder with the INPA.INI from your saved CFGDAT folder.
Code:
C:>copy X:CFGDATINPA.INI C:EC-APPSINPACFGDAT /v /y1 file(s) copied.
Copy the INPA scripts and configuration files from your saved CFGDAT and SGDAT folders.
Code:
C:>copy X:CFGDAT*.ENG C:EC-APPSINPACFGDAT /v14 file(s) copied.
Then C:>copy X:SGDAT*.IPO C:EC-APPSINPASGDAT /v468 file(s) copied.
C:>copy X:SGDAT*.SRC C:EC-APPSINPASGDAT /v11 file(s) copied.
C:>copy X:SGDAT*.TXT C:EC-APPSINPASGDAT /v2 file(s) copied.
Now copy the group files from the SP Daten E89 folder to C:EDIABASECU.
Code:
C:>copy X:E89ECU*.GRP C:EDIABASECU /v80 file(s) copied.
Then import your daten files into WinKFP using this guide (steps 2-8)
Create a C:NCSEXPERDATENE89 folder and then copy the contents of the E89DATEN folder into it.
Code:
C:>mkdir C:NCSEXPERDATENE89C:>
copy X:E89DATEN*.* C:NCSEXPERDATENE89 /v430 file(s) copied.
Then copy the contents of the E89SGDAT folder to C:NCSEXPERSGDAT.
Code:
C:>copy X:E89SGDAT*.* C:NCSEXPERSGDAT /v224 file(s) copied.
Go to the E89DATEN directory and execute the LADEN.BAT script.
Code:
C:>cd X:E89DATENX:E89DATEN>laden.bat
You’ll receive errors at the end of the script due to the missing C:EC-APPSCARSERVER directory, ignore them.
Install the patched 32-bit NCS Expert from this thread:
http://www.e90post.com/forums/showthread.php?t=832476
Example:
Code:
Rename C:NCSEXPERBINNCSEXPER.EXE NCSEXPER.OLD
Then rename C:NCSEXPERCFGDATNCSEXPER.TXT NCSEXPER.GER
copy NCSEXPER.EXE C:NCSEXPERBIN /v
copy NCSEXPER.TXT C:NCSEXPERCFGDAT /v
Then copy the NCS Expert profiles to the C:NCSEXPERPFL folder.
Example:
Code:
copy *.PFL C:NCSEXPERPFL /v
Ok, finished and congratulations!
VXDAS team kindly note:
It’s better to install the BMW INPA software in Windows XP, it will be more stable when use.
Bmw Inpa 4.4 7 Download Pc
Here is the installation guide of Win XP for INPA software:
Professional Diagnostic Solution & Service Supplier
Website:www.vxdas.com
Bmw Inpa 4.4 7 Download 32-bit
Follow Us To Get More Free Resource